chemical tanker guide
Chemical hazards || Various chemicals || Cargo Stowage || Care ||Tank cleaning ||Handling equipments || Home

Chemical tankers cargo instruments - Alarms and shutdown circuits

An important feature of many modern measurement and control instruments is the ability to signal a particular situation. This can be a main operational alarm that gives an indication of a pre-set situation such as liquid level in a tank, or a malfunction alarm indicating a failure within a sensor's own operating mechanism. The designs and purposes of alarm and shutdown circuits vary widely, and their operating system may be pneumatic, hydraulic, electrical or electronic. Safe operation of plant and systems depends on the correct operation of these circuits and a knowledgeable reaction to them.



chemical tanker navigation at sea
The following precautions should be observed:

i) where provided, test facilities should be used before cargo operations commence, to check that the circuits and their alarms are operating: any instrument fault should be rectified;

ii) wiring inside and outside cabinets should be checked for chafing, condensation, insulation deterioration, bad connections etc;

iii) watchkeepers should be instructed how to distinguish between each audible alarm and what action is necessary;

iv) the accuracy of all inputs to alarm circuits should be checked;

v) if an alarm is activated, the cause must be investigated and necessary remedial action taken;

vi) if an alarm circuit becomes defective during cargo operations, it should be repaired as soon as possible. Defective circuits may be by-passed temporarily in case of an emergency, but this action should only be taken with the full agreement of the responsible officer and the decision should be recorded. Completion of the repair work should also be recorded.

It should be borne in mind that individual ship has got own characteristics and limitations may involved handling various chemical cargoes . The master and all personnel in all cases must be aware of cargo/ship information that has been given and comply with relevant safety procedures.


Other info pages

Draegar Chemical detector tubes use and reading correction guideline
These instruments, often referred to as Draeger tubes, normally function by drawing a sample of the atmosphere to be tested through a proprietary chemical reagent in a glass tube. The detecting reagent becomes progressively discoloured if a contaminant vapour is present in the sample. The length of the discoloration stain gives a measure of the concentration of the chemical vapour which can be read from the graduated scale printed on the tube. Detector tubes give an accurate indication of chemical vapour concentration, whatever the oxygen content of the mixture

Requirements of various grade chemical cargo heating
: The voyage orders will contain heating information, if heating is required. As a rule the final heating instructions are given by the Shipper in writing to the Master / Chief Officer in the port of loading. If those written instructions are not given, the master should request them and issue a Letter of Protest if they are not received at departure. In the latter case the management office should be immediately informed.


Recommended temperature monitoring equipments onboard
:Temperature sensors are fitted so that the temperature of the cargo can be monitored, especially where required by the IBC Code. It is important to know the cargo temperature in order to be able to calculate the weight of cargo on board, and because tanks or their coatings often have a maximum temperature limit. Many cargoes are temperature sensitive, and can be damaged by overheating or if permitted to solidify. Sensors may also be fitted to monitor the temperatures of the structure around the cargo system.

Cargo instruments
:In order to maintain a proper control of the tank atmosphere and to check the effectiveness of gas freeing, especially prior to tank entry, several different gas measuring instruments need to be available for use. Which one to use will depend upon the type of atmosphere being measured.

Liquid level gauges
:The accuracy required of chemical carrier level gauges is high because of the nature and value of the cargo. To limit personnel exposure to chemicals or their vapours while cargo is being handled, or during carriage at sea, the IBC Code specifies three methods of gauging the level of a liquid in a tank - open, restricted or closed

Overflow control
:Certain cargoes require the designated tank to be fitted with a separate high level alarm to give warning before the tank becomes full. The alarm may be activated by either a float operating a switch device, a capacitive pressure transmitter, or an ultrasonic or radioactive source. The activation point is usually pre-set at 95% of tank capacity.

Oxygen analysers
:Oxygen analysers are normally used to determine the oxygen level in the atmosphere of an enclosed space: for instance, to check that a cargo tank can be considered fully inerted, or whether a compartment is safe for entry.

Vapour detection
:Ships carrying toxic or flammable products (or both) should be equipped with at least two instruments that are designed and calibrated for testing the gases of the products carried. If the instruments are not capable of testing for both toxic concentrations and flammable concentrations, then separate sets of instruments should be provided.

Alarm circuit
:An important feature of many modern measurement and control instruments is the ability to signal a particular situation. This can be a main operational alarm that gives an indication of a pre-set situation such as liquid level in a tank, or a malfunction alarm indicating a failure within a sensor's own operating mechanism. The designs and purposes of alarm and shutdown circuits vary widely, and their operating system may be pneumatic, hydraulic, electrical or electronic. Safe operation of plant and systems depends on the correct operation of these circuits and a knowledgeable reaction to them.

Gas freeing
:Gas freeing onboard chemical tankers is required for entry into cargo tanks, for hot works or washing for clean ballast tanks. Gas Freeing is one of the most hazardous operations routinely undertaken onboard a Chemical Tanker and the additional risk created by cargo gases expelled from the tanks, which may be toxic, flammable and corrosive, cannot be over-emphasised.

Cargo tank damage during pigging operations
:Blowing and pigging of pipelines at terminals poses inherent risks for the terminal and a chemical tanker. Frequent damages to tanks have occurred. If there are doubts about the shore operation or signs of problems ashore the OOW must immediately request clarification.


Reference publications







Main Info pages!

Home page ||| Chemical hazards ||| Cargo planning & Stowage ||| Cargo loading ||| Cargo documents ||| Safe stability ||| Cargo care ||| Preparation for unloading ||| Inert gas systems |||Gas freeing ||| Nitrogen handling ||| Chemical handling Safe practice |||Handling equipments ||| Cargo & Ballast pumps ||| Cargo tanks |||Tank cleaning |||Special cargoes |||Spills emergencies |||Fire protection



Chemicaltankerguide.com is merely an informational site about various aspects of chemical tankers and safety tips that may be particular value to those working in: Chemical Handling, Chemical Storage, Liquefied Chemical Suppliers, Chemical Shipping, Chemical Transportation, Chemical Terminals, Bulk Chemical Services and Chemical Processing. If you are interested in finding out more about chemical tanker guideline please visit IMO official website. For any comment please Contact us